| Specification | Details |
|---|---|
| Code | ATEC-PH001 |
| Dosing Pump Capacity | 1.5 L/h @ 1.5 bar |
| Dimensions | 218 × 125 × 95 mm |
| Input | 100–220 V AC +10% |
| Power | 5 W |
| Control Interface | LCD screen, 4-key keyboard and menu system |
| Dosing Operation | Alternating pause/run cycles of 100 seconds during acid injection |
| Alarm | Stand-by alarm display due to no flow in probe holder |
| Included | pH electrode, probe holder, pH calibration solution, fixing brackets, connection and installation kit |
Sacrificial Anode – Protective barrier against electrolytic corrosion
Recommended to be used with salt chlorinators, this zinc sacrificial anode protects pool equipment from electrolytic corrosion. It acts as a protective barrier for metal components such as stainless steel ladders, heat pumps and exchangers, UV-C stainless steel casings, lighting niches and face rings, aluminum pump motor housings and titanium cell plates in salt chlorinators. For optimal performance, the anode should be replaced once approximately 50% of the material has eroded, typically after around three years of use.
Specifications
- Easy installation design by adding inline to existing 63mm /
- 2” piping system
- Excellent electric shock prevention in fiberglass pools
- 4 Bar working pressure
- Long-life pure zinc alloy anode
- 1m 8 AWG solid copper wire and transparent lid for inspection